Archicad 17 SOLO Hotfix Build 5020
Release Notes for Archicad 17 Solo Hotfix Build 5020
This Hotfix makes the trial functions of EcoDesigner STAR available in countries where the product is available for Archicad 17 Solo (United Kingdom, Ireland). This Hotfix includes important fixes for bugs discovered since the original release of Archicad 17 Solo (Build 3017). This Hotfix can be applied to any builds of Archicad 17 Solo (Build 3017 and above).
This Hotfix applies to Archicad and all other components: BIMx, MEP and all Graphisoft-distributed Add-ons and Goodies.
Installation notes
- Make sure you have administrator rights on the computer. Start the full installation process using an administrator account. For Mac users make sure to mount the installation dmg while being signed in with the administrator account that you always use to install or patch Graphisoft products. Make sure none of the Archicad components are modified (e.g. renamed).
-
When you run the hotfix package, the process will automatically search for Archicad on your computer. You can choose to either update it or not.
- If you have multiple copies of Archicad on your machine, the installer will automatically find one copy. If you want to update a different instance, you can use the “Browse” button to locate it. You will need to run the installer multiple times to update each copy of Archicad.
List of bugs fixed in this Hotfix
Changes since the release of Hotfix 3 (Build 5015)
- Trial functions of EcoDesigner STAR are now available in selected markets.
Bugs fixed since the release of Hotfix 1 (Build 4301)
- 162393 DOCUMENT: Full layouts and sections of particular projects could become rotated. You can read more about the issue here: Help Center
- 164080 DOCUMENT: If in the Work Environment the User Preference Schemes -> More Options -> Do not launch new instance of Archicad when placing a view onto Layout setting was checked, drawings could not be placed, only an empty frame appeared.
- 165550 DOCUMENT: Interactive Schedule didn’t show the Integer value list properly.
- 160250 DOCUMENT: mulitplane roof pitch was not listed properly.
- 143997 DOCUMENT: Particular symbol fill could cause large PDF file.
- 158237 DOCUMENT: PDF saved on Windows and opened in Preview on a MAC (or placed into Archicad) rendered unreadable text with faulty tracking. Read more about the issue here: Help Center
- 159404 DOCUMENT: Reviewer did notwork with newer Java applets.
- 159411 DOCUMENT: Some Master Layouts hid Elements with New Renovation Status.
- 148152 DOCUMENT: When listing objects in Interactive Schedule there was no criteria referring the Zone that they were placed in.
- 158118 DOCUMENT: Zones which were overridden by renovation and MVO lost their renovation override style in the saved and printed pdf.
- 163334 EDIT: Align Texture was working erroneously with curved and slanted beams.
- 163331 EDIT: Aling Texture’s Set Origin worked erroneously on curved walls.
- 158581 EDIT: Changed IFC properties weren’t kept when saving a Favorite from the Element.
- 161572 EDIT: After copy-pasting Story-linked elements to the upmost story, they loose their linked status.
- 161862 EDIT: Crash could occur when adjusting Editing plane.
- 165558 EDIT: Editing a mesh could cause crash.
- 165270 EDIT: First floor could not be selected as scheduling criteria in the following language versions: CZE, CHI, JPN, NOR, RUS, USA
- 164347 EDIT: Force Guide Line command didn’t work with the Door, Window tools.
- 161123, 162933 EDIT: If a parameter of an object was changed in section or elevation view, when switched to another section/elevation view the object would not be updated.
- 160818 EDIT: If Resize command was used repeatedly to modify an element, Resize ratio values once set were not retained in the element’s pop-up window.
- 164149 EDIT: If you mirror a fill with the Area text display on then after editing the mirrored fill the area text got dispositioned.
- 163894 EDIT: In section selecting and changing grouped elements did not have an effect on the invisible elements.
- 165052 EDIT: Placing Doors and Windows Using Special Snap Constraint went wrong when guide line was active.
- 162129 EDIT: Position of a traced detail on another detail view could be inconsistent.
- 157406 EDIT: Status of zones with geometry method changed from “Manual” to “Inner Edge” were incorrect and they couldn’t be updated.
- 160927 EDIT: Surface renovation override did not work for Morph.
- 163783 EDIT: Updating zones could cause crash in certain situations.
- 160814 EDIT: When heights of hotspots of mesh were edited one after the other the last used command were not retained by Pet Palette.
- 160310, 163982 EDIT: Windows with Custom Corner and Corner Windows were not placed where the first feedback showed.
- 163889 EDIT: Could not paste rich text or figure into Archicad.
- 159768 ENERGY EVALUATION: Central Boiler Unmet Load Hours was erroneously calculated under certain circumstances.
- 161508 ENERGY EVALUATION: Cooling’s and Ventilation’s auxiliary system data were missing from Report.xls.
- 160025 ENERGY EVALUATION: Default system characteristics of a new cooling machine were wrong.
- 165033 ENERGY EVALUATION: Discrepancy could appear in solar radiation percentage of openings.
- 165218 ENERGY EVALUATION: Energy Evaluation calculation didn’t finish and an error message appeared.
- 160923 ENERGY EVALUATION: In particular files sewage calculation was wrong if Local Heat Pump was used for Service Hot Water Generation.
- 162053 ENERGY EVALUATION: Service Hot Water Heating and Sewage didn’t appear on the Energy Balance in certain circumstances.
- 159888 ENERGY EVALUATION: Setting BoilerSystem -> Heat Loss value could cause erroneous efects on the simulation result.
- 165258 ENERGY EVALUATION: Solar absorptance unit was missing in case of Tree View
- 166044 ENERGY EVALUATION: Switching between radio buttons on the Climate Data dialog could crash Archicad.
- 161037 ENERGY EVALUATION: The Cooling quantity in the report didn’t match with the quantity in the xls.
- 161507 ENERGY EVALUATION: The Target of the Renewable Energy Source was missing from the 2nd and 3rd bar charts of the Report.PDF’s Energy Consumption by Sources chapter, if Heat Pump or Solar collector is used for heating.
- 163880 ENERGY EVALUATION: Warning message could appear in Energy evaluation because some polygons weren’t segmented.
- 161509 ENERGY EVALUATION: With particular file Auxiliary Electricity appears on Report.pdf if District Cooling was used.
- 160058 ENERGY EVALUATION: With particular file Central Cooling Machine was unable to meet cooling demand, even with maximum capacity.
- 161589 ENERGY EVALUATION: With particular file Cooling Energy Quantity was wrong in the Energy Consumption chapters of the Report.pdf.
- 160922 ENERGY EVALUATION: With particular file Energy Consumption calculation of Heat Pumps used for Service Hot Water Heating was wrong.
- 161454 ENERGY EVALUATION: With particular file Energy source and target quantities were wrong on Report.pdf if cooling machine was used.
- 161465 ENERGY EVALUATION: With particular file Peak Cooling data was wrong on Report.pdf if cooling machine was used.
- 161489 ENERGY EVALUATION: With particular file Primary Energy calculation of heat pump for heating was wrong.
- 160944 ENERGY EVALUATION: With particular file Sewage calculation was wrong if Central Heat Pump was used for Service Hot Water Generation.
- 162001 ENERGY EVALUATION: With particular file Solar Collector Type setting had no effect on calculation.
- 163905 FILE/DWG/EXPORT/ÖNORM: Only attributes with values were exported to DWG.
- 163928 FILE/DWG/EXPORT/ÖNORM: Text settings of zones’ text blocks were lost.
- 163191 FILE/DWG/EXPORT: A specific combination of template and translator settings caused DWG export to resulte in a 0kb faulty DWG file.
- 165560 FILE/DWG/IMPORT: Relinking, opening DWG could cause crash.
- 159637 FILE/EXPORT/PDF: Trace Reference wasn’t exported to PDF if Rotated Orientation was set and there were Elements far from Origin.
- 164938 FILE/EXPORT/SKETCHUP: Usage of national characters in the add-ons directory resulted in the export of a 0 kb sketchup file.
- 164496 FILE/IFC: Improved export and import of large models.
- 159569 FILE/IFC/EXPORT: Element quantities can be exported into custom properties. Read more about this here: Help Center
- 162596 FILE/IFC/EXPORT: IFC Quantities ‘GrossFloorArea’ and ‘NetFloorArea’ were switched upon IFC export.
- 143209 FILE/IFC/EXPORT: Openings with slanted reveal might look incorrect in IFC.
- 161549 FILE/IFC/EXPORT: Warning message that “Some elements could not be exported due to missing geometry” appeared after exporting empty openings.
- 163271 FILE/IFC/IMPORT: After importing a particular IFC file 2D symbol of doors were missing and viewing their settings brought up error message.
- 165612 FILE/IFC/IMPORT: If the column settings in the default template had a veneer, IFC imported columns would inherit this veneer.
- 147046 FILE/IFC/IMPORT: Wall niche became an opening when imported into Archicad.
- 161699 FILE/MIGRATION: After migrating a file containing elements very far from the origin the coordinates of elements could double.
- 165203 FREEZE: A mouse clicked in certain regions close to a spline could make Archicad unresponsive.
- 163057 FREEZE: Non-responsive behaviour occurred when background processing of 3d elements refused to allow user interaction.
- 160731 FREEZE: On Mac Archicad seemed to be freezing due to the fact that the publishing window came back behind the main Archicad window after switching between applications.
- 163391 GDL: CALL function couldn’t be rebuild, when it was used for macro name.
- 163791 INSTALL: Hotfix or additional installations could only be made by the same user who had installed Archicad because limted permission of the newly created folders.
- 163409 MODEL: After deleting a wall and then undoing the operation the original intersection geometry with a roof was not restored.
- 157576 MODEL: Align 3D command didn’t work on polygonal Walls.
- 161498 MODEL: Align 3D Texture commands had no effect on Beams.
- 162032 MODEL: Checking and correcting code was added to better handle 3D junction data.
- 161832 MODEL: Curved beams didn’t cut walls.
- 163209 MODEL: Sun and sky objects did not work with marquee.
- 165856 MODEL: textures with alpha channel appeared incorrectly with black patches on OS X 10.9 Mavericks.
- 165619 MODEL: When a Wall-end was placed with a height parameter lower then the floor cut plane, window related error message erroneously appeared.
- 156754 SPEED: Slowdown or freeze could happen while having multiple Archicad instances running side by side.
- 156759 USER INTERFACE: Navigating in 2D using 3Dconnexion Space Navigator worked in wrong direction.
- 165663 USER INTERFACE: When using Archicad on two displays palettes with left side title bar could get inaccessible on MAC OS X 10.9 after dragging them to the border area between two displays.
Bugs fixed since the Main Release (Build 3017)
- 156094 API: Transformation data of rotated views could not be retrieved or set through API.
- 131177 CRASH: Archicad could crash during IFC export.
- 155118 CRASH: The routines that addressed 3D projections were made more stable.
- 157462 CRASH: In particular projects opening the project or pasting 2D elements could cause Archicad to crash.
- 157557 CRASH: Crash could occur when stretching a Fill with the Marquee tool.
- 159613 CRASH: Both an erroneous visible Archicad Layer and its resulting crash were corrected.
- 159685 CRASH: Crash could occur when starting energy simulation.
- 161434 CRASH: Some files containing incorrect wall/slab junction points caused Archicad to crash on open.
- 158319 CRASH (FRA): French Archicad could crash when rendering with Sketch engine.
- 134515 DOCUMENT: Display of Beams did not reflect the position of the Floor Plan Cut Plane below and above the Home Story.
- 148311 DOCUMENT: Story numbers were also visible in Schedule fields that should have shown only the names.
- 157548 DOCUMENT: Built in common Interior Elevation Marker displayed incorrect outer references. All the references were the same.
- 159140 DOCUMENT: Zone Category was not listed in the Schedule.
- 160332 DOCUMENT: On MAC OS platforms Energy Evaluation report could not be saved in some localized version (RUS, POL). For more information read this article: http://archicadwiki.com/Troubleshooting/WorkaroundForSavingXlsInEnergyEvaluation
- 158545 DOCUMENT (JPN): ± sign appeared incorrectly in the Interactive Schedule of JPN version.
- 145593 EDIT: Interior Elevation Marker was rotated when limit line was extended.
- 148586 EDIT: Preview of materials could disappear when switching between different rendering engines in the Surface Settings dialog.
- 156091 EDIT: In Section/Elevation when modifying a wall using the pet palette Stretch Height command, numeric values entered into the tracker’s Offset to Home Story or Offset to Top Linked Story fields were ignored.
- 156273 EDIT: Unnecessary hotspots could appear on roofs.
- 157183 EDIT: If fill was mirrored before in a given view, and the view is then rotated by more than 90 degrees then the fill’s area text would not be dragged to the desired position.
- 157639 EDIT: After activating a Morph favorite, the layer and Building Material was not transferred.
- 158203 EDIT: Relink Home Story didn’t work for grouped elements unless the group is suspended.
- 158535 EDIT: Morph favoritesweren’t applied when using double clicking.
- 159537 EDIT: Adjust function didn’t work between walls and other elemet types.
- 159747 EDIT: Automatic Story association changes when accidentally moving the element across the story level line in Section/Elevation: http://archicadwiki.com/AutomaticHomeStoryAssignmentRefined
- 160131 EDIT: If cutting plane was defined in 3D, the snap points of the Stories on the guide line were not available.
- 160137 EDIT: object created from a section (Create Patch) could not be edited because it contained a Building Material.
- 160184 EDIT: Fill Orientation of Building Materials could change if more than one was selected in the dialog.
- 160553 EDIT: Markup Style field picked up attributes unnecessarily with every copy/paste.
- 159364 EDIT/DOCUMENT: Modifying Wall Reference Line did not automatically update dimensions associated to the wall. Only moving an end-point of the wall triggered the update.
- 157437 EDIT (NOR): Space Saver Staircase couldn’t be placed in NOR version.
- 157537 ENERGY EVALUATION: When autotext was inserted into the header/footer of the Evaluation Report, it could delete the existing content.
- 158400 ENERGY EVALUATION: The energy demand of Auxiliary System could be erroneously calculated.
- 158654 ENERGY EVALUATION: Solar Analysis didn’t work with windows shown with a single surface in simple viewing method.
- 158880 ENERGY EVALUATION: When importing Operation Profile attributes their Internal temperature Min/Max values were reset to off.
- 160106 ENERGY EVALUATION: In some particular circumstances solar radiation calculation for windows could give wrong results.
- 160233 ENERGY EVALUATION: After running solar analysis the leaves of a plant object disappeared. Placing the element again didn’t help.
- 159657 FILE/ARTLANTIS/SAVE: Archicad 17 could not save Artlantis 4.1 file if another Artlantis 4.1 file was used as reference.
- 158717 FILE/DWG/EXPORT (AUT): Certain objects could be exported to dwg file with wrong sizes if ÖNORM translator were used.
- 158352 FILE/DWG/IMPORT: Import Blocks from DXF/DWG caused Archicad to crash.
- 147239 FILE/IFC/DATA: Find & Select and Interactive Element Schedule work for IFC Type Product and IFC assignments data.
- 156971 FILE/IFC/DATA: The Merge function of the IFC Scheme Setup command now opens the IFC Schemes 17 folder by default.
- 160970 FILE/IFC/DATA: IFC name attribute was not descriptive enough. A mapping file was created that is user modifiable that contains a set of rules formatted in xml to bring data from different fields in an Archicad project into the IFC Name Attribute field. For more information please read this article:
- http://archicadwiki.com/TechTips/IFCNameAttributeMapping
- 161707 FILE/IFC/DATA: If there is no active MEP Modeler Add-on, the properties of MEP-type elements were not saved after clicking ‘OK’ in the Element Settings dialog.
- 159906 FILE/IFC/EXPORT: Extended Model View export now can be made based on Coordination View 2.0 using a registry key. For how to set up the registry key in question, please read this article: http://archicadwiki.com/RegistryKeys/UseCoordinationView2ForExtendedModelView
- 161208 FILE/IFC/EXPORT: After opening a particular IFC file exported from Archicad 17 in Revit 2014, the width values of some doors show 0.9 mm instead of 900 mm.
- 158841 FILE/IFC/IMPORT: Space Containment data of zones are now imported even if the Zone itself cannot be imported.
- 159199 FILE/IFC/IMPORT: At IFC import IFC Container elements were not correctly registered which in some cases could lead to TW errors.
- 159286 FILE/IFC/IMPORT: Archicad crashed when opening particular IFC file.
- 159431 FILE/IFC/IMPORT: Certain IFC files could be opened in Archicad 16 but not in 17.
- 160068 FILE/IFC/IMPORT: Elements that were part of a Space Container were not imported if that particular space did not have a geometry.
- 161503 FILE/IFC/IMPORT: IfcWalls defined in a specific coordination system were placed with incorrect position upon import.
- 159536 FILE/IMPORT: Import standard Steel Profile: Unit display was not correct, the decimal separator was at wrong place in case of cm’s
- 156934 FILE/MIGRATION: Projected display of particular user created windows could differ in Archicad 17 after migrating the file from previous Archicad versions.
- 159812 FILE/OPEN: File couldn’t be opened if it contained a Roof having 0 length Pivot line.
- 161157 FILE/OPEN: Arch Length dimensions placed in Archicad 16 could cause the plan ti fail to open in Archicad 17.
- 159954 FILE/OPEN/CRASH: File could crash at opening if it contained invalid polygons. (Polylines/Fills with nodes too close to each other)
- 148255 INSTALL: Hotfix installation on the BIM Server could fail if multiple users are logged into the server OS.
- 159675 INSTALL: Windows could mark the hotfix installer as being published by Unknown source. The digital signature of GRAPHISOFT has been corrected.
- 162575 INSTALL: Installer could not run successfully if logged in as a Domain Administrator.
- 128573 MODEL: Modeling particular dormer structure from Multi roof elements left incorrect roof intersections.
- 158077 MODEL: A tube Morph wasn’t solid if the beginning and ending faces overlapped.
- 159509 MODEL: Fit to skin function didn’t work with Shell tool.
- 160134 MODEL: Vectorial hatching alignment could be wrong on particular Multiplane Roofs.
- 160409 MODEL: 2D intersection of curved profiled walls might have been dependent on the zoom level.
- 159241 SPEED: Zone schedule calculations could be slow in certain cases.
- 159753 SPEED: Drawing Manager check status updates are now faster.
- 161089 SPEED: Hidden Edges could cause freeze in certain 3D Document views.
- 158771 VIEW: Projected display of Corner Windows were wrong in PBC mode in particular cases.
- 159266 VIEW: Zooming in 3D window in Object Mode worked in the wrong direction with 3Dconnexion Mouse.
- 160194 VIEW: Partial Structure Display error could occur in 3D Floor Plan Document views when Trace was used.
- 161571 VIEW: Label Renovation status behaved different depending on the display order.
- 161657 VIEW: Curved Composite Walls weren’t visible on a Reflected Ceiling Plan 3D Document in the Legacy Intersection method.
- 158090 BIMx: On Windows activating the Crouch function caused the BIMx window to become inactive until clicking beside the BIMx window or pressing a key.
- 159051 BIMx: Elements cut by a Cutplane with the “Use Element Attributes” setting in the “Cut Elements in 3D” dialog were flickering during BIMx navigation.
- 159442 BIMx: BIMx file saved from Archicad 17 could open with version of BIMx Viewer 16.
- 159659 BIMx: Erroneous setting option for Lightmap quality is now removed from interface.
- 159706 BIMX: Overwriting a .BIMx file while saving it resulted in its disappearance.
- 160159 BIMx: BIMx file saved with the “Create Single Movie…” option from an Archicad project containing multiple camera paths could cause BIMx crash.
- 161182 BIMx: The rotation value of a texture in BIMx was one hundredth of the same value in Archicad.
Download this Hotfix
Download | Language | Windows | Mac OSX | Last modified | |
Archicad 17 Solo Hotfix 4 (Build 5020) | INT | 166.1 MB | 167.2 MB | Jan 29, 2014 |